使用WMI监视进程的创建活动
问题描述:
我使用WMI监视进程创建事件使用WMI监视进程的创建活动
根据其他职位(How to detect win32 process creation/termination in c++)
我按照它来注册我的回调函数,但它不工作。
什么都没有发生,当我运行这个程序,并打开IEXPLORE
请帮帮我,谢谢
#define _WIN32_DCOM
#include <iostream>
using namespace std;
#include <comdef.h>
#include <Wbemidl.h>
#include <atlcomcli.h>
#pragma comment(lib, "wbemuuid.lib")
#include "CreationEvent.h"
class EventSink : public IWbemObjectSink {
friend void CreationEvent::registerCreationCallback(TNotificationFunc callback);
CComPtr<IWbemServices> pSvc;
CComPtr<IWbemObjectSink> pStubSink;
LONG m_IRef;
CreationEvent::TNotificationFunc m_callback;
public:
EventSink(CreationEvent::TNotificationFunc callback) :m_IRef(0), m_callback(callback){}
~EventSink(){
}
virtual ULONG STDMETHODCALLTYPE AddRef() {
return InterlockedIncrement(&m_IRef);
}
virtual ULONG STDMETHODCALLTYPE Release() {
LONG IRef = InterlockedDecrement(&m_IRef);
if (IRef == 0)
delete this;
return IRef;
}
virtual HRESULT STDMETHODCALLTYPE QueryInterface(REFIID riid, void** ppv) {
if (riid == IID_IUnknown || riid == IID_IWbemObjectSink) {
*ppv = (IWbemObjectSink*) this;
AddRef();
return WBEM_S_NO_ERROR;
}
else return E_NOINTERFACE;
}
virtual HRESULT STDMETHODCALLTYPE Indicate(
LONG lObjectCount,
IWbemClassObject __RPC_FAR *__RPC_FAR *apObjArray
){
m_callback();
/* Unregister event sink */
pSvc->CancelAsyncCall(pStubSink);
return WBEM_S_NO_ERROR;
}
virtual HRESULT STDMETHODCALLTYPE SetStatus(LONG IFlags, HRESULT hResult, BSTR strParam, IWbemClassObject __RPC_FAR *pObjParam) {
return WBEM_S_NO_ERROR;
}
};
void CreationEvent::registerCreationCallback(TNotificationFunc callback) {
CComPtr<IWbemLocator> pLoc;
CoInitialize(NULL);
HRESULT hres = CoCreateInstance(CLSID_WbemLocator, 0, CLSCTX_INPROC_SERVER, IID_IWbemLocator, (LPVOID*)&pLoc);
if (FAILED(hres)) {
cout << "Failed to create IWbemLocator object."
<< " Err code = 0x"
<< hex << hres << endl;
throw std::exception("CreationEvent initialization failed");
}
CComPtr<EventSink> pSink(new EventSink(callback));
hres = pLoc->ConnectServer(_bstr_t(L"ROOT\\CIMV2"), NULL, NULL, 0, NULL, 0, 0, &pSink->pSvc);
if (FAILED(hres)) {
cout << "Could not connect. Error code = 0x" << hex << hres << endl;
throw std::exception("CreationEvent initialization failed");
}
hres = CoSetProxyBlanket(pSink->pSvc, RPC_C_AUTHN_WINNT, RPC_C_AUTHZ_NONE, NULL, RPC_C_AUTHN_LEVEL_CALL, RPC_C_IMP_LEVEL_IMPERSONATE, NULL, EOAC_NONE);
if (FAILED(hres)) {
cout << "Coult not set proxy blanket, Error code =0x" << hex << hres << endl;
throw std::exception("CreationEvent initialization failed");
}
CComPtr<IUnsecuredApartment> pUnsecApp;
hres = CoCreateInstance(CLSID_UnsecuredApartment, NULL, CLSCTX_LOCAL_SERVER, IID_IUnsecuredApartment, (void**)&pUnsecApp);
CComPtr<IUnknown> pStubUnk;
pUnsecApp->CreateObjectStub(pSink, &pStubUnk);
pStubUnk->QueryInterface(IID_IWbemObjectSink, (void**)&pSink->pStubSink);
char buffer[512];
sprintf_s(buffer, "SELECT * FROM __InstanceCreationEvent WITHIN 1 WHERE TargetInstance ISA 'Win32_Process' AND TargetInstance.Name = 'iexplore.exe'");
hres = pSink->pSvc->ExecNotificationQueryAsync(_bstr_t("WQL"), _bstr_t(buffer), WBEM_FLAG_SEND_STATUS, NULL, pSink->pStubSink);
if (FAILED(hres)) {
cout << "ExecNotificationQueryAsync failed with = 0x" << hex << hres << endl;
throw std::exception("CreationEvent initialization failed");
}
}
void k() { cout << "KKKKK " << endl; }
int main() {
CreationEvent::registerCreationCallback(k);
cin.get();
}
CreationEvent.h
#pragma once
#ifndef _CreationEvent_h__
#define _CreationEvent_h__
#include <boost/function.hpp>
namespace CreationEvent {
typedef boost::function<void(void)> TNotificationFunc;
void registerCreationCallback(TNotificationFunc callback);
}
#endif
答
回去,并审阅本文Example: Receiving Event Notifications Through WMI,并发现了一个显然重要的区别。
在方法CreationEvent::registerCreationCallback(...)
,替换:
CoInitialize(NULL);
有:
CoInitializeEx(0, COINIT_MULTITHREADED);
+0
谢谢你的帮助,它的工作原理!我没有注意到-Ex之间的区别。 –
+0
很高兴听到,很高兴帮助! –
建议 - 尝试省略'AND TargetInstance.Name =“iexplore.exe''条款,以确保您的回调当任何*进程启动时调用。如果有效,请尝试排除其他过滤条件。 –
我曾尝试过,但它不起作用 –